# Pipestra Support (beta) - formulas, sources and limitations Pipestra Support checks simple steel pipe supports to EN 1993-1-1: single post, T-post, portal frame, cantilever bracket and a simple pipe rack (2 posts, 1 or 2 tiers). It is an engineering aid only. Results must be verified by a qualified engineer. No liability. All calculations run in the browser; nothing is uploaded. ## 1. Axes, units, loads - Internal axes: X across the support (along the beam), Y up, Z along the pipe. With "Z up" input (pipe stress convention) the loads are mapped internal = (Fx, Fz, -Fy) and results are mapped back. - Units: kN, m, kNm. E = 210 000 MPa, G = 81 000 MPa, steel density 7850 kg/m3 (EN 1993-1-1 3.2.6). - Pipe loads are loads on the support (force of the pipe on the steel), applied as concentrated forces at the pipe axis: point x on the member, pipe axis at height e above the top of steel (lever arm h/2 + e to the member axis). Moments Mx My Mz entered per point are added. On UPN members the load acts at mid-width of the top flange, i.e. with a lever (b/2 - ys + ym) to the shear centre (torsion). - Load cases SUS / OPE / OCC; combinations are editable (default ULS-1 1.35 SUS, ULS-2 1.35 OPE, ULS-3 1.00 OCC, SLS-1 1.00 OPE; steel self-weight with its own factor). ## 2. Structural analysis - Own linear-elastic 3D frame solver: 2-node Euler-Bernoulli beam elements, 6 DOF per node (12x12 element matrix incl. St Venant torsion GIt). Member end releases (pinned joints) are modelled with extra rotational DOFs. Uniform loads (self-weight) as work-equivalent nodal loads. Mechanisms are detected (zero pivot) and reported. - Elastic critical load factor alpha_cr (EN 1993-1-1 5.2.1): geometric stiffness of the posts (global sway), smallest positive eigenvalue of (K + alpha Kg) phi = 0 by shifted power iteration, cross-checked against a positive-definiteness bisection in the tests. alpha_cr >= 10: first-order analysis. 3 <= alpha_cr < 10: all action effects multiplied by 1/(1 - 1/alpha_cr) (5.2.2(5)B). alpha_cr < 3: rejected (second-order analysis needed). - Sway imperfections (5.3.2(3)a): phi = phi0 alpha_h alpha_m, phi0 = 1/200, alpha_h = 2/sqrt(h) within [2/3, 1], alpha_m = sqrt(0.5 (1 + 1/m)). Applied as equivalent horizontal forces phi x vertical load at the pipe points and on the self-weight, separately in +X, -X, +Z, -Z (each a separate variant of the combination). Neglected where H >= 0.15 V (5.3.2(4)). - Warping torsion (non-uniform torsion, Vlasov): per member a 1D finite-element model with DOFs (phi, phi') and stiffness EIw (Hermite) + GIt (string). Cantilevers: twist and warping fixed at the root; spans and posts of frames: fork supports. Bimoment B(s) -> warping normal stress sigma_w = B omega_max / Iw with omega_max = (h - tf) b / 4 for I/H sections (UPN: from the shear-centre position). ## 3. Sections and material - HEA 100-600, HEB 100-600, IPE 80-600, UPN 80-400 (72 sections). Dimensions to EN 10365:2017; properties (A, Iy, Iz, Wel, Wpl, Avz, It, Iw, ys, ym) from: ArcelorMittal Europe - Long Products, Sections and Merchant Bars, Sales Programme 2026-V3, which states "Dimensions: EN 10365:2017": https://constructalia.arcelormittal.com/files/V2026_3_Sales%20programme_FR_EN_DE--123b7234b68e0b1b5576b03bb791a537.pdf - Verification (automated tests): 1. Every value in the library equals the published table (72 sections). 2. A, Iy, Iz, Wel, Wpl of all I/H sections recomputed from the EN 10365 dimensions h, b, tw, tf, r (own formulas incl. root fillets) agree within 1 %, It within 1.5 % (fillet formula), Iw within 2 %. 3. Mass G = 0.785 A within 1.5 % for all 72 sections. 4. Second source: British Steel "EN sections" datasheet (20.07.26), https://www.britishsteel.co.uk/wp-content/uploads/2026/07/EN-sections-all-datasheet-20.07.26-1.pdf - 47 IPE/HE sections matched; h, b, tw, tf identical for all 47; for the 28 sections with the same root radius A, Iy, Iz, Wpl, It, Iw agree within 1 % or the datasheet's rounding step. (British Steel uses larger root radii for some sizes, e.g. HE 200 A r = 20 instead of 18 mm; those are listed in refs/bs_crosscheck.json but not used.) 5. The published section classes (bending and compression, S355 and S460) are reproduced by the classification routine for all 72 sections. - Steel S235 / S355, fy by thickness (EN 1993-1-1 Table 3.1: t <= 40 mm 235 / 355 MPa, 40 < t <= 80 mm 215 / 335 MPa; governing t = max(tf, tw)). gamma_M0, gamma_M1 editable (default 1.00, recommended values; check the national annex). ## 4. Member checks (EN 1993-1-1) - Classification (5.5, Table 5.2): flange outstand c = (b - tw - 2r)/2 in compression; web c = h - 2tf - 2r under the actual N + My (alpha method for class 1/2, psi for class 3). Class 4 is reported as not covered. - Cross-section (6.2), evaluated at 10 stations per element for every ULS variant; the utilisation is the inverse of the load multiplier at which the criterion reaches 1 (found by bisection), so that non-linear interaction formulas give a meaningful eta: - N: 6.2.3 / 6.2.4; V: 6.2.6 with Av (Avz from the table; Avy = A - hw tw); torsion: tau_t = T t_max / It vs fy/(sqrt3 gamma_M0) and Vpl,T,Rd (6.2.7(9), eq. 6.26); warping normal stress sigma_w added linearly to the N + M criterion. - Bending and shear: rho = (2 V/Vpl,Rd - 1)^2 for V > 0.5 Vpl,Rd (6.2.8). - N + My + Mz: class 1/2 I/H 6.2.9.1 (6.36, 6.38) with the biaxial criterion (6.41), alpha = 2, beta = max(1, 5n); UPN and class 3: linear sum (6.2.1(7) / 6.2.9.2). - Flexural buckling (6.3.1): chi from curves Table 6.2 (rolled I/H: h/b > 1.2: a/b, else b/c; UPN: c), lambda_bar = Lcr/(i lambda1), lambda1 = pi sqrt(E/fy). - Buckling lengths: single post and T-post (cantilever) 2H; frame posts in-plane: sway factor k = sqrt((1 - 0.2(eta1 + eta2) - 0.12 eta1 eta2) / (1 - 0.8(eta1 + eta2) + 0.6 eta1 eta2)) with distribution coefficients eta from column and beam stiffness (beam K = 1.5 I/L in sway, ENV 1993-1-1 Annex E / NCCI SN008); out of plane 2 x height (unbraced) or the segment length (braced along the pipe); beams: span or arm length; user overrides possible in the file. - Lateral-torsional buckling (6.3.2.2, general case): chi_LT from Table 6.4 (rolled I: h/b <= 2 curve a, else b; others d); Mcr from the three-factor formula (k = kw = 1): Mcr = C1 pi^2 E Iz / L^2 [ sqrt(Iw/Iz + L^2 G It/(pi^2 E Iz) + (C2 zg)^2) - C2 zg ], C1 = (1.33 - 0.33 psi)^2 for linear diagrams (Table 6.6 kc), else 1.0; top-flange loads zg = h/2, C2 = 0.63 (destabilising, optional); cantilevers C1 = 1 with L_LT = k a (default k = 2.0, editable). - Interaction (6.3.3, Annex B method 2): Tables B.1 / B.2 (B.2 used when chi_LT < 1, i.e. members susceptible to torsional deformation), Cm from Table B.3 (0.6 + 0.4 psi >= 0.4 for linear diagrams; 0.9 for sway modes; 1.0 for cantilevers). - Shear buckling: hw/tw <= 72 eps checked (6.2.6(6)); otherwise a warning (EN 1993-1-5 not covered). ## 5. Serviceability - Deflection of spans relative to the chord vs L/n (default 200), cantilever tips vs 2a/n (default 200, equivalent span of a cantilever), horizontal sway of post tops sqrt(ux^2 + uz^2) vs H/n (default 150). Limits are editable; they are common project values, not binding code values. ## 6. Validation (tests/engine.test.mjs, node --test) Closed-form checks: cantilever PL^3/3EI (both axes) and root moment; simply supported UDL 5wL^4/384EI and wL^2/8; fixed-fixed central load PL/8 and PL^3/192EI; hinged joint (end release); portal with rigid beam H h^3/(24 E I); St Venant twist TL/GIt; Euler loads (pinned and cantilever columns, power iteration = bisection); mechanism detection; global equilibrium of reactions for every variant of all five templates; Z-up mapping. Vlasov closed forms (cantilever B(0) = T tanh(lambda L)/lambda, tip twist; fork span B_mid = T/(2 lambda) tanh(lambda L/2)). EN 1993-1-1 values against an independent Python hand calculation (tools/hand_calc.py): flexural buckling (HEA 180), Mcr and chi_LT (IPE 200, also with destabilising load), plastic N + My + Mz (HEA 200), Annex B beam-column (HEA 160), Table B.3 / 6.6 factors, imperfection and sway length factor. ## 7. Not covered in v1 (known limitations) - Joints, base plates, anchors, welds, bolts, bracing members, foundations. - Second-order analysis (only amplification for 3 <= alpha_cr < 10), member imperfections in the global analysis (covered by the member checks 6.3), class 4 sections, shear buckling, local load introduction (web crippling / patch loading, EN 1993-1-5 section 6), flange local bending under shoes. - Friction is not generated; enter it as Fx / Fz loads. No seismic, wind, fatigue or fire checks. - Torsion: shear-centre eccentricity only for loads on UPN flanges and through the lever arm e; warping boundary conditions are idealised (cantilever root fully restrained, spans forked). - Rack: 2 posts and 1 or 2 tiers only; longitudinal bracing is modelled as a rigid restraint at beam level when ticked (the bracing itself is not checked).